To begin we must apply heat to the back cover, and with the help of a flat tool we will remove all the edges of the casing
Step 2 Fingerprint reader connector
We extract the Phillips screw (PH # 00) that holds the shield that covers the connector and we can disconnect it.
Step 3 Upper housing
We extract the seven Phillips screws (PH # 00) that hold the intermediate housing, and with the help of a flat tool we will remove it.
Step 4 Side push buttons
We disconnect the flex that we are going to change, we remove the protective plastic that is above the zone of the pulsadores, and with the help of a metallic prick we will take off the damaged pushbuttons.
Video Tutorial summary
In this video you can watch a quick summary of the tutorial, but we recommend to follow the complete tutorial, with its explanations and detailed images.